Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Language
Document Type
Year range
1.
Viruses ; 14(11)2022 Oct 31.
Article in English | MEDLINE | ID: covidwho-2099850

ABSTRACT

BACKGROUND: Investigating antibody titers in individuals who have been both naturally infected with SARS-CoV-2 and vaccinated can provide insight into antibody dynamics and correlates of protection over time. METHODS: Human coronavirus (HCoV) IgG antibodies were measured longitudinally in a prospective cohort of qPCR-confirmed, COVID-19 recovered individuals (k = 57) in British Columbia pre- and post-vaccination. SARS-CoV-2 and endemic HCoV antibodies were measured in serum collected between Nov. 2020 and Sept. 2021 (n = 341). Primary analysis used a linear mixed-effects model to understand the effect of single dose vaccination on antibody concentrations adjusting for biological sex, age, time from infection and vaccination. Secondary analysis investigated the cumulative incidence of high SARS-CoV-2 anti-spike IgG seroreactivity equal to or greater than 5.5 log10 AU/mL up to 105 days post-vaccination. No re-infections were detected in vaccinated participants, post-vaccination by qPCR performed on self-collected nasopharyngeal specimens. RESULTS: Bivariate analysis (complete data for 42 participants, 270 samples over 472 days) found SARS-CoV-2 spike and RBD antibodies increased 14-56 days post-vaccination (p < 0.001) and vaccination prevented waning (regression coefficient, B = 1.66 [95%CI: 1.45-3.46]); while decline of nucleocapsid antibodies over time was observed (regression coefficient, B = -0.24 [95%CI: -1.2-(-0.12)]). A positive association was found between COVID-19 vaccination and endemic human ß-coronavirus IgG titer 14-56 days post vaccination (OC43, p = 0.02 & HKU1, p = 0.02). On average, SARS-CoV-2 anti-spike IgG concentration increased in participants who received one vaccine dose by 2.06 log10 AU/mL (95%CI: 1.45-3.46) adjusting for age, biological sex, and time since infection. Cumulative incidence of high SARS-CoV-2 spike antibodies (>5.5 log10 AU/mL) was 83% greater in vaccinated compared to unvaccinated individuals. CONCLUSIONS: Our study confirms that vaccination post-SARS-CoV-2 infection provides multiple benefits, such as increasing anti-spike IgG titers and preventing decay up to 85 days post-vaccination.


Subject(s)
COVID-19 , Humans , COVID-19/prevention & control , Antibody Formation , SARS-CoV-2 , Prospective Studies , COVID-19 Vaccines , Antibodies, Viral , Vaccination , Immunoglobulin G
2.
Int J Infect Dis ; 114: 178-182, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1487753

ABSTRACT

This article reports a case of a 21-year-old woman with refractory B-cell acute lymphocytic leukaemia who presented with severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). She remained positive for SARS-CoV-2 by viral culture for 78 days and by polymerase chain reaction (PCR) for 97 days. Sequencing of repeat samples over time demonstrated an increasing and dynamic repertoire of mutations.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Female , Humans , Immunocompromised Host , Mutation , Virus Shedding , Young Adult
3.
J Clin Virol ; 142: 104914, 2021 09.
Article in English | MEDLINE | ID: covidwho-1313214

ABSTRACT

BACKGROUND: SARS-CoV-2 antibody testing is required for estimating population seroprevalence and vaccine response studies. It may also increase case identification when used as an adjunct to routine molecular testing. We performed a validation study and evaluated the use of automated high-throughput assays in a field study of COVID-19-affected care facilities. METHODS: Six automated assays were assessed: 1) DiaSorin LIAISONTM SARS-CoV-2 S1/S2 IgG; 2) Abbott ARCHITECTTM SARS-CoV-2 IgG; 3) Ortho VITROSTM Anti-SARS-CoV-2 Total; 4) VITROSTM Anti-SARS-CoV-2 IgG; 5) Siemens SARS-CoV-2 Total Assay; and 6) Roche ElecsysTM Anti-SARS-CoV-2. The validation study included 107 samples (42 known positive; 65 presumed negative). The field study included 296 samples (92 PCR positive; 204 PCR negative or not PCR tested). All samples were tested by the six assays. RESULTS: All assays had sensitivities >90% in the field study, while in the validation study, 5/6 assays were >90% sensitive and DiaSorin was 79% sensitive. Specificities and negative predictive values were >95% for all assays. Field study estimated positive predictive values at 1-10% disease prevalence were 100% for Siemens, Abbott and Roche, while DiaSorin and Ortho assays had lower PPVs at 1% prevalence, but PPVs increased at 5-10% prevalence. In the field study, addition of serology increased diagnoses by 16% compared to PCR testing alone. CONCLUSIONS: All assays evaluated in this study demonstrated high sensitivity and specificity for samples collected at least 14 days post-symptom onset, while sensitivity was variable 0-14 days after infection. The addition of serology to the outbreak investigations increased case detection by 16%.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , British Columbia , Humans , Immunoassay , Sensitivity and Specificity , Seroepidemiologic Studies
SELECTION OF CITATIONS
SEARCH DETAIL